Excellent version design effectivelyenhances module output power.
The gain of double-sided powergeneration increases with the backlight exposure,reaching up to 25% significantly reducing LCOE.
Minimize the probability of attenuationcaused by PlD phenomenon throughoptimization ofbattery productionte chnology and material control.
The first year attenuation is less than1.0%,with alinear attenuation of 0.4% per year for 30 years.
Quality assurance
Power guarantee
annual decay
Cell | N-type TOPCon(156) |
Dimensions | 2465±2mmx1134±2mmx30±1mm |
Weight | 35kg±3% |
Glass | 2.0mm AR coating heatstrengthened glass,low iron |
Frame | Anodized aluminium alloy |
junctionbox | IP68,3 diodes |
Wireway | 4mm²,350mm(+)/350mm(-) or Customized Length |
Packaging | 36 pieces/pallet |
Loadingquantity | 40 HC:720pieces; 13 meter truck:720pieces; |
Maxsystem voltage | 1500V DC |
-OT | -40°C~+85°C |
Fuse's rated current | 25A |
Maxload,front | 5400Pa |
Maxload,back | 2400Pa |
-NOCT | 45±2°C |
Backside rate | 80%±5°C |
safety level | Class Ⅱ |
Fire performance | UL Type Ⅰ |
Model | JKL156-B-615NB | JKL156-B-620NB | JKL156-B-625NB | JKL156-B-630NB | ||||||||||||||||||||||||
STC/NOCT |
|
|
|
| ||||||||||||||||||||||||
Pmax [W] |
|
|
|
| ||||||||||||||||||||||||
Vmp [V] |
|
|
|
| ||||||||||||||||||||||||
Imp [A] |
|
|
|
| ||||||||||||||||||||||||
Voc [V] |
|
|
|
| ||||||||||||||||||||||||
Isc [A] |
|
|
|
| ||||||||||||||||||||||||
EFF [%] | 22.01% | 22.18% | 22.36% | 22.54% | ||||||||||||||||||||||||
Powertolerance (w) | 0~+5W | |||||||||||||||||||||||||||
Short circuit current temperature coefficient (a_lsc) | +0.046%/℃ | |||||||||||||||||||||||||||
Open circuit voltage temperature coefficient (B-Voc) | -0.250%/°C | |||||||||||||||||||||||||||
Maximum power temperature coefficient (y_Pmp) | -0.300%/°C | |||||||||||||||||||||||||||
Standard test conditions(STc) | lrradiance 1000W/m²,Cell temperature 25°C,Spectral AM1.5 | |||||||||||||||||||||||||||
Nominal battery operating temperature (NOCT) | lrradiance 800W/m², Ambient temperature 20℃, Spectrum AM1.5, Wind speed 1m/s |
Note: The electrical performance parameters in this product catalog do not only refer to a single module, nor are they promised in the contract.The electrical parameters are only used for comparison between different module types.