Effectively reduce system BOS costs achieve lower electricity consumption costs,and improve project profitability.
Adopting new generation cell technology and optimizing circuit design to achieve better temperature coeficient and thermal resistance.
Adopting large-sized and highly efficient cells,applying efficiency enhancing packaging materials and half cut technology to improve power output.
Single glass structure and layout design that have been validated by long-term market applications.
Quality assurance
Power guarantee
Annual decay
Cell | N-type TOPCon(108) |
Dimensions | 1722±2mm×1134±2mm×30±1mm |
Weight | 21kg±3% |
Glass | 3.2mm AR coating tempered glass,low iron |
Frame | Anodized aluminium alloy |
junctionbox | IP68,3 diodes |
Wireway | 4mm²,350mm(+)/350mm(-)or customized length |
Packaging | 36pieces/pallet |
Loading quantity | 20GP:216 pieces ,40GP:432 pieces ,40HQ:936pieces,13 meter truck:936pieces,17.5 meter truck:1152pieces |
Maxsystem voltage | 1500V DC |
Operating Temperature | -40℃ ~+85℃ |
Fuse's rated current | 25A |
Maxload front | 5400Pa |
Maxload back | 2400Pa |
Cell nominal operating temperature | 45±2°C |
Safety level | Class ll |
Fire performance | UL Type l |
Model | JKL108-B-420NH | JKL108-B-425NH | JKL108-B-430NH | JKL108-B-435NH | JKL108-B-440NH | ||||||||||
STC/NOCT |
|
|
|
|
| ||||||||||
Maximum power [W] |
|
|
|
|
| ||||||||||
Maximum working voltage [V] |
|
|
|
|
| ||||||||||
Maximum working current [A] |
|
|
|
|
| ||||||||||
Open circuit voltage [V] |
|
|
|
|
| ||||||||||
Short circuit current [A] |
|
|
|
|
| ||||||||||
EFF [%] | 21.52% | 283% | 22.02% | 22.31% | 22.53% | ||||||||||
Power tolerance [W] | 0 ~+5W | ||||||||||||||
Short circuit current temperature coefficient | +0.046%/℃ | ||||||||||||||
Open circuit voltage temperature coefficient | -0.250%/℃ | ||||||||||||||
Maximum power temperature coefficient | -0.300%/℃ | ||||||||||||||
STC | Irradiance 1000W/m², Cell temperature 25°C,Spectral AM1.5 | ||||||||||||||
NOCT | lrradiance 800W/m², Ambient temperature 20℃, Spectrum AM1.5, Wind speed 1m/s |
Note: The electrical performance in this product catalog do not only refer to a single module, or are they promised in the contract. The electrical parameters are only used for comparison between different module types.